Skip to content
Get a Quote + Certificate

Coordinate Measuring Machines

CMM Calibration and Repair

Request a quotation for calibration or repair of a coordinate measuring machine.

Request a quotation

StandardISO/IEC 17025:2017CoverageWestern Pennsylvania and the Upper Ohio Valley

Pricing is set out in writing and sent by email.

Scope of Calibration

Bridge, gantry and cantilever CMMs and portable articulated arms are calibrated under ISO/IEC 17025:2017. Length measurement error and probing performance are checked against the machine's stated specification, and the environment around the machine, temperature, vibration and foundation condition, is noted where it affects the result.

Repair is scoped separately from calibration. The failure is documented in an as-found report before any repair work is authorized, covering scales, bearings, air bearings, probe heads and controller faults.

What Gets Checked

Calibration follows documented procedures for axis performance, volumetric accuracy and probe qualification, with results reviewed before release.

  • 01

    Linear error

    Axis positioning checked along each travel using traceable length standards.

  • 02

    Volumetric performance

    Length measurement error verified across the working volume per the applicable test.

  • 03

    Probe qualification

    Probing error and repeatability checked against a calibrated reference sphere.

  • 04

    Repair diagnostics

    Scale, bearing and controller faults isolated before a repair quotation is issued.

  • 05

    Environmental check

    Temperature, vibration and foundation conditions are noted against the machine's specification.

How a Request Moves

  • 01

    Request review

    Machine model, controller and access window are reviewed before scheduling.

  • 02

    As-found data

    Baseline measurements are recorded before any adjustment is made.

  • 03

    Calibration or repair

    Adjustment, repair or replacement is performed as scoped and approved.

  • 04

    Certificate issued

    As-left data, uncertainty and reference standards are stated on the report.

Why Pittsburgh CMM Calibration and Repair

  • 01

    As-found reporting

    Failures are documented before adjustment so drift history is not lost.

  • 02

    Repair scoped separately

    Diagnosis is completed first, and the repair quotation follows it.

  • 03

    Portable and fixed machines

    Bridge, gantry, cantilever and articulated-arm CMMs are all covered.

Coverage across Western Pennsylvania and the Upper Ohio Valley

Service is coordinated across Western Pennsylvania and the Upper Ohio Valley. Availability of on-site versus depot service varies by equipment type and location.

Discuss CMM Calibration and Repair Requirements

Submit machine details to receive a calibration or repair quotation.

Pricing is set out in writing and sent by email.
Get a Quote + CertificateEmail us